Manual mode means that the system generates heated airflow when the cycle button is pressed; when it is pressed a second time the system shuts off. "Timed" modes allow the operator to create up to 20 "Profiles" that consist of time and temperatures parameters to ensure process control and repeatability. Both cycle start and vacuum functions are activated with conveniently located switches on the handpiece.
The handpiece is fitted with an adjustable, spring loaded vacuum pik to lift components from the PCB and to hold the component in the nozzle during alignment. The "give" in the spring loading is set, but the absolute position of the vacuum pik is adjustable over a 1.5" length.
Features
- Multi-level password lock-out prevents unauthorized changes
- User definable temperature zone
- Audible countdown timer for end of cycle indication in the Timed and Program modes
- On-screen display of parameters (temperature, time) during operation
- Store and recall up to 20 profiles (40 with optional software)
- Quiet-Flo turbine blower offers nearly silent operation
- Hi-Flo Vacuum Pump for holding component securely
- Lo-Flo Vacuum Pump for component wand
Product Number
8007-0429
| FEATURES/SPECIFICATIONS | |
| Power Requirements: | 197-253 VAC, 50/60 Hz, 575Watts max. |
| Dimensions: | 134mm H x 245mm W x 264mm D (5.25" H x 10" W x 10.4" D) |
| Weight: | 4.5Kg (9.9lbs.) |
| Temperature Control: | Closed loop, digital temperature control |
| Temperature stability: | ° 9°C (° 15 °F) at idle tip temp. |
| Temperature Range: | 176°to 482°C (350°to 900°F) nominal |
| Airflow: | 5-22 slpm |